[*] Emulating binary name: trattcom
[*] Emulator used: qemu-arm-static
[*] Using root directory: /logs/s115_usermode_emulator/firmware/patool_extraction/rootfs.img_unblob_extracted/rootfs.img_extract/0-80367616.squashfs_v4_le_extract (1/2)
[*] Using CPU config:
[*] Emulating binary: /usr/bin/trattcom
[*] Change permissions +x to /logs/s115_usermode_emulator/firmware/patool_extraction/rootfs.img_unblob_extracted/rootfs.img_extract/0-80367616.squashfs_v4_le_extract/./usr/bin/trattcom.
[*] Emulating binary ./usr/bin/trattcom with parameter NONE
[*] Emulating binary ./usr/bin/trattcom with parameter -v
Option parsing failed: Missing argument for -v
Failed to open port
Failed to open/initialize serial port, exiting..
[*] Emulating binary ./usr/bin/trattcom with parameter -V
===== trattcom starting... (TID 3)
fd-1 = /dev/ttymxc1 (baudrate = 4000000)
Failed to open port
Failed to open/initialize serial port, exiting..
===== trattcom exiting..
[*] Emulating binary ./usr/bin/trattcom with parameter -h
Usage:
trattcom [OPTION?]
Interactive mode is entered if the port parameter is missing.
Help Options:
-h, --help Show help options
Application Options:
-x, --version Print version and exit.
-d, --device Serial device (try ls /dev/serial/by-id) [default /dev/ttymxc1]
-b, --baud_rate Baud rate to use when opening serial connection [default 4000000]
-l, --list List available ports (for non interactive use).
-p, --port Port to set/get, if port_value (-v) or threshold (-r) or blink (-B) are missing, a get is assumed
-v, --value Port value to set
-D, --direction Port direction request
-B, --blink Port blink high:low:initial
-t, --timeout Timeout for a command in non-interactive mode (default 2 seconds)
-T, --temperature Get junction temperature
-V, --verbose Verbose console output
-r, --add_threshold Add ADC threshold value
-R, --delete_threshold Delete ADC threshold value
-L, --list_thresholds List ADC thesholds
-X, --target_version Show target version
-m, --target_md5 Show target MD5 version
-u, --target_uptime Show target uptime (in seconds)
-q, --enable_wiegand_1 Enable Wiegand 1 driver
-Q, --disable_wiegand_1 Disable Wiegand 1 driver
-w, --enable_wiegand_2 Enable Wiegand 2 driver
-W, --disable_wiegand_2 Disable Wiegand 2 driver
-g, --digpot Set digital potentiometer output (0-255)
--rs485_send_dev RS485 send USART device
--rs485_test_dev RS485 test USART device
--rs485_string RS485 string to send/receive (default 'test')
Examples:
Enter interactive mode
$trattcom
Set port X5 (EN_READER) to value 1
$trattcom -p X5 -v 1
or
$trattcom -p EN_READER -v 1
Set port C9 to value 0, connect on /dev/ttyUSB0 @ 115200, timeout 3 seconds
$trattcom -d /dev/ttyUSB0 -b 115200 -p C9 -v 0 -t 3
Get port value C8
$trattcom -p C8
Set a threshold value on A0 to 500 AD units
$trattcom -p A0 -r 500
Delete the threshold value on A0 with 500 AD units
$trattcom -p A0 -R 500
List existing thesholds
$trattcom -L
Set blink mode on A0 200ms high, 200ms low starting with high state
$trattcom -p A0 -B 200:200:1
Get the direction of port B6
$trattcom -p B6 -D
[*] Emulating binary ./usr/bin/trattcom with parameter -help
Usage:
trattcom [OPTION?]
Interactive mode is entered if the port parameter is missing.
Help Options:
-h, --help Show help options
Application Options:
-x, --version Print version and exit.
-d, --device Serial device (try ls /dev/serial/by-id) [default /dev/ttymxc1]
-b, --baud_rate Baud rate to use when opening serial connection [default 4000000]
-l, --list List available ports (for non interactive use).
-p, --port Port to set/get, if port_value (-v) or threshold (-r) or blink (-B) are missing, a get is assumed
-v, --value Port value to set
-D, --direction Port direction request
-B, --blink Port blink high:low:initial
-t, --timeout Timeout for a command in non-interactive mode (default 2 seconds)
-T, --temperature Get junction temperature
-V, --verbose Verbose console output
-r, --add_threshold Add ADC threshold value
-R, --delete_threshold Delete ADC threshold value
-L, --list_thresholds List ADC thesholds
-X, --target_version Show target version
-m, --target_md5 Show target MD5 version
-u, --target_uptime Show target uptime (in seconds)
-q, --enable_wiegand_1 Enable Wiegand 1 driver
-Q, --disable_wiegand_1 Disable Wiegand 1 driver
-w, --enable_wiegand_2 Enable Wiegand 2 driver
-W, --disable_wiegand_2 Disable Wiegand 2 driver
-g, --digpot Set digital potentiometer output (0-255)
--rs485_send_dev RS485 send USART device
--rs485_test_dev RS485 test USART device
--rs485_string RS485 string to send/receive (default 'test')
Examples:
Enter interactive mode
$trattcom
Set port X5 (EN_READER) to value 1
$trattcom -p X5 -v 1
or
$trattcom -p EN_READER -v 1
Set port C9 to value 0, connect on /dev/ttyUSB0 @ 115200, timeout 3 seconds
$trattcom -d /dev/ttyUSB0 -b 115200 -p C9 -v 0 -t 3
Get port value C8
$trattcom -p C8
Set a threshold value on A0 to 500 AD units
$trattcom -p A0 -r 500
Delete the threshold value on A0 with 500 AD units
$trattcom -p A0 -R 500
List existing thesholds
$trattcom -L
Set blink mode on A0 200ms high, 200ms low starting with high state
$trattcom -p A0 -B 200:200:1
Get the direction of port B6
$trattcom -p B6 -D
[*] Emulating binary ./usr/bin/trattcom with parameter --help
Usage:
trattcom [OPTION?]
Interactive mode is entered if the port parameter is missing.
Help Options:
-h, --help Show help options
Application Options:
-x, --version Print version and exit.
-d, --device Serial device (try ls /dev/serial/by-id) [default /dev/ttymxc1]
-b, --baud_rate Baud rate to use when opening serial connection [default 4000000]
-l, --list List available ports (for non interactive use).
-p, --port Port to set/get, if port_value (-v) or threshold (-r) or blink (-B) are missing, a get is assumed
-v, --value Port value to set
-D, --direction Port direction request
-B, --blink Port blink high:low:initial
-t, --timeout Timeout for a command in non-interactive mode (default 2 seconds)
-T, --temperature Get junction temperature
-V, --verbose Verbose console output
-r, --add_threshold Add ADC threshold value
-R, --delete_threshold Delete ADC threshold value
-L, --list_thresholds List ADC thesholds
-X, --target_version Show target version
-m, --target_md5 Show target MD5 version
-u, --target_uptime Show target uptime (in seconds)
-q, --enable_wiegand_1 Enable Wiegand 1 driver
-Q, --disable_wiegand_1 Disable Wiegand 1 driver
-w, --enable_wiegand_2 Enable Wiegand 2 driver
-W, --disable_wiegand_2 Disable Wiegand 2 driver
-g, --digpot Set digital potentiometer output (0-255)
--rs485_send_dev RS485 send USART device
--rs485_test_dev RS485 test USART device
--rs485_string RS485 string to send/receive (default 'test')
Examples:
Enter interactive mode
$trattcom
Set port X5 (EN_READER) to value 1
$trattcom -p X5 -v 1
or
$trattcom -p EN_READER -v 1
Set port C9 to value 0, connect on /dev/ttyUSB0 @ 115200, timeout 3 seconds
$trattcom -d /dev/ttyUSB0 -b 115200 -p C9 -v 0 -t 3
Get port value C8
$trattcom -p C8
Set a threshold value on A0 to 500 AD units
$trattcom -p A0 -r 500
Delete the threshold value on A0 with 500 AD units
$trattcom -p A0 -R 500
List existing thesholds
$trattcom -L
Set blink mode on A0 200ms high, 200ms low starting with high state
$trattcom -p A0 -B 200:200:1
Get the direction of port B6
$trattcom -p B6 -D
[*] Emulating binary ./usr/bin/trattcom with parameter --version
Version: 8c99674
Machine: A1610
[*] Emulating binary ./usr/bin/trattcom with parameter version
Failed to open port
Failed to open/initialize serial port, exiting..
-----------------------------------------------------------------